Ubuntu: Is this error ever can be solved?



Question:

Having trouble to boot as bios and format my hard as MBR ( even GPT is not working ) here is a screenshot for further details

and when I ran smartctl -a /dev/sda I get the following output

 === START OF INFORMATION SECTION ===  Model Family:     Seagate Samsung SpinPoint M8 (AF)  Device Model:     ST750LM022 HN-M750MBB  Serial Number:    S2RRJ9BD306196  LU WWN Device Id: 5 0004cf 209eebf94  Firmware Version: 2AR10002  User Capacity:    750,156,374,016 bytes [750 GB]  Sector Sizes:     512 bytes logical, 4096 bytes physical  Rotation Rate:    5400 rpm  Form Factor:      2.5 inches  Device is:        In smartctl database [for details use: -P show]  ATA Version is:   ATA8-ACS T13/1699-D revision 6  SATA Version is:  SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)  Local Time is:    Mon Oct  2 19:34:45 2017 EET  SMART support is: Available - device has SMART capability.  SMART support is: Enabled    === START OF READ SMART DATA SECTION ===  SMART overall-health self-assessment test result: PASSED    General SMART Values:  Offline data collection status:  (0x00) Offline data collection activity                      was never started.                      Auto Offline Data Collection: Disabled.  Self-test execution status:      ( 121) The previous self-test completed having                      the read element of the test failed.  Total time to complete Offline   data collection:        (10140) seconds.  Offline data collection  capabilities:            (0x5b) SMART execute Offline immediate.                      Auto Offline data collection on/off support.                      Suspend Offline collection upon new                      command.                      Offline surface scan supported.                      Self-test supported.                      No Conveyance Self-test supported.                      Selective Self-test supported.  SMART capabilities:            (0x0003) Saves SMART data before entering                      power-saving mode.                      Supports SMART auto save timer.  Error logging capability:        (0x01) Error logging supported.                      General Purpose Logging supported.  Short self-test routine   recommended polling time:    (   2) minutes.  Extended self-test routine  recommended polling time:    ( 169) minutes.  SCT capabilities:          (0x003f) SCT Status supported.                      SCT Error Recovery Control supported.                      SCT Feature Control supported.                      SCT Data Table supported.    SMART Attributes Data Structure revision number: 16  Vendor Specific SMART Attributes with Thresholds:  ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE    1 Raw_Read_Error_Rate     0x002f   100   100   051    Pre-fail  Always       -       28010    2 Throughput_Performance  0x0026   252   252   000    Old_age   Always       -       0    3 Spin_Up_Time            0x0023   089   059   025    Pre-fail  Always       -       3463    4 Start_Stop_Count        0x0032   097   097   000    Old_age   Always       -       3780    5 Reallocated_Sector_Ct   0x0033   252   252   010    Pre-fail  Always       -       0    7 Seek_Error_Rate         0x002e   252   252   051    Old_age   Always       -       0    8 Seek_Time_Performance   0x0024   252   252   015    Old_age   Offline      -       0    9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       12630   10 Spin_Retry_Count        0x0032   252   252   051    Old_age   Always       -       0   11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always       -       260   12 Power_Cycle_Count       0x0032   097   097   000    Old_age   Always       -       3356  191 G-Sense_Error_Rate      0x0022   100   100   000    Old_age   Always       -       804  192 Power-Off_Retract_Count 0x0022   252   252   000    Old_age   Always       -       0  194 Temperature_Celsius     0x0002   060   041   000    Old_age   Always       -       40 (Min/Max 15/59)  195 Hardware_ECC_Recovered  0x003a   100   100   000    Old_age   Always       -       0  196 Reallocated_Event_Count 0x0032   252   252   000    Old_age   Always       -       0  197 Current_Pending_Sector  0x0032   100   099   000    Old_age   Always       -       3  198 Offline_Uncorrectable   0x0030   252   252   000    Old_age   Offline      -       0  199 UDMA_CRC_Error_Count    0x0036   098   098   000    Old_age   Always       -       1404  200 Multi_Zone_Error_Rate   0x002a   100   100   000    Old_age   Always       -       2133  223 Load_Retry_Count        0x0032   100   100   000    Old_age   Always       -       260  225 Load_Cycle_Count        0x0032   088   088   000    Old_age   Always       -       128226    SMART Error Log Version: 1  ATA Error Count: 277 (device log contains only the most recent five errors)      CR = Command Register [HEX]      FR = Features Register [HEX]      SC = Sector Count Register [HEX]      SN = Sector Number Register [HEX]      CL = Cylinder Low Register [HEX]      CH = Cylinder High Register [HEX]      DH = Device/Head Register [HEX]      DC = Device Command Register [HEX]      ER = Error register [HEX]      ST = Status register [HEX]  Powered_Up_Time is measured from power on, and printed as  DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,  SS=sec, and sss=millisec. It "wraps" after 49.710 days.    Error 277 occurred at disk power-on lifetime: 12509 hours (521 days + 5 hours)    When the command that caused the error occurred, the device was active or idle.      After command completion occurred, registers were:    ER ST SC SN CL CH DH    -- -- -- -- -- -- --    84 51 00 00 4f c2 a0  Error: ABRT      Commands leading to the command that caused the error were:    CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name    -- -- -- -- -- -- -- --  ----------------  --------------------    b0 d0 00 00 4f c2 a0 00      00:00:00.008  SMART READ DATA    b0 d0 00 00 4f c2 a0 00      00:00:00.008  SMART READ DATA    b0 d8 00 00 4f c2 a0 00      00:00:00.008  SMART ENABLE OPERATIONS    f8 00 00 00 00 00 e0 00      00:00:00.008  READ NATIVE MAX ADDRESS [OBS-ACS-3]    ec 00 00 00 00 00 a0 00      00:00:00.006  IDENTIFY DEVICE    Error 276 occurred at disk power-on lifetime: 12509 hours (521 days + 5 hours)    When the command that caused the error occurred, the device was active or idle.      After command completion occurred, registers were:    ER ST SC SN CL CH DH    -- -- -- -- -- -- --    84 51 00 00 00 00 a0      Commands leading to the command that caused the error were:    CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name    -- -- -- -- -- -- -- --  ----------------  --------------------    ec 00 00 00 00 00 a0 00      00:00:00.006  IDENTIFY DEVICE    Error 275 occurred at disk power-on lifetime: 12509 hours (521 days + 5 hours)    When the command that caused the error occurred, the device was active or idle.      After command completion occurred, registers were:    ER ST SC SN CL CH DH    -- -- -- -- -- -- --    84 51 00 00 4f c2 a0  Error: ABRT      Commands leading to the command that caused the error were:    CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name    -- -- -- -- -- -- -- --  ----------------  --------------------    b0 d1 00 00 4f c2 a0 00      00:00:00.018  SMART READ ATTRIBUTE THRESHOLDS [OBS-4]    b0 d0 00 00 4f c2 a0 00      00:00:00.018  SMART READ DATA    b0 d8 00 00 4f c2 a0 00      00:00:00.018  SMART ENABLE OPERATIONS    27 00 00 00 00 00 e0 00      00:00:00.018  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]    ec 00 00 00 00 00 a0 00      00:00:00.015  IDENTIFY DEVICE    Error 274 occurred at disk power-on lifetime: 12291 hours (512 days + 3 hours)    When the command that caused the error occurred, the device was active or idle.      After command completion occurred, registers were:    ER ST SC SN CL CH DH    -- -- -- -- -- -- --    40 51 08 20 a7 58 ed  Error: UNC 8 sectors at LBA = 0x0d58a720 = 223913760      Commands leading to the command that caused the error were:    CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name    -- -- -- -- -- -- -- --  ----------------  --------------------    c8 00 08 20 a7 58 ed 00      00:00:54.028  READ DMA    ca 00 08 70 21 46 e9 00      00:00:54.028  WRITE DMA    ea 00 00 00 00 00 e0 00      00:00:54.028  FLUSH CACHE EXT    ca 00 38 38 21 46 e9 00      00:00:54.028  WRITE DMA    ef 10 02 00 00 00 a0 00      00:00:54.028  SET FEATURES [Enable SATA feature]    Error 273 occurred at disk power-on lifetime: 12291 hours (512 days + 3 hours)    When the command that caused the error occurred, the device was active or idle.      After command completion occurred, registers were:    ER ST SC SN CL CH DH    -- -- -- -- -- -- --    40 51 08 20 a7 58 ed  Error: UNC 8 sectors at LBA = 0x0d58a720 = 223913760      Commands leading to the command that caused the error were:    CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name    -- -- -- -- -- -- -- --  ----------------  --------------------    c8 00 08 20 a7 58 ed 00      00:00:54.026  READ DMA    c8 00 08 18 a7 58 ed 00      00:00:54.026  READ DMA    c8 00 08 10 a7 58 ed 00      00:00:54.026  READ DMA    c8 00 08 08 a7 58 ed 00      00:00:54.026  READ DMA    c8 00 08 00 a7 58 ed 00      00:00:54.026  READ DMA    SMART Self-test log structure revision number 1  Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error  # 1  Short offline       Completed: read failure       90%     12630         1465144320  # 2  Extended offline    Aborted by host               60%     12630         -  # 3  Short offline       Completed: read failure       90%     12629         1465144320  # 4  Extended offline    Aborted by host               90%     12629         -  # 5  Short offline       Completed: read failure       90%     12628         1465144320  # 6  Extended offline    Aborted by host               90%     12628         -  # 7  Short offline       Completed: read failure       90%     12628         1465144320  # 8  Short offline       Completed: read failure       90%     12628         1465144320  # 9  Extended offline    Interrupted (host reset)      90%     12510         -  #10  Short offline       Completed: read failure       90%     12510         1465144320  #11  Extended offline    Aborted by host               70%     12484         -  #12  Short offline       Completed: read failure       90%     12483         1139114040  #13  Extended offline    Aborted by host               90%     12384         -  #14  Short offline       Completed: read failure       90%     12384         1465147904  #15  Short offline       Completed: read failure       90%     12384         1465147904  #16  Short offline       Completed: read failure       90%     12381         310080928  #17  Short offline       Completed: read failure       90%     12381         310080928    SMART Selective self-test log data structure revision number 0  Note: revision number not 1 implies that no selective self-test has ever been run   SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS      1        0        0  Completed_read_failure [90% left] (0-65535)      2        0        0  Not_testing      3        0        0  Not_testing      4        0        0  Not_testing      5        0        0  Not_testing  Selective self-test flags (0x0):    After scanning selected spans, do NOT read-scan remainder of disk.  If Selective self-test is pending on power-up, resume after 0 minute   delay.  

I also get the same error as in this question on boot up

can someone help? can't find any solution anywhere


Solution:1

The HDD was failing as said in the above comments


Note:If u also have question or solution just comment us below or mail us on toontricks1994@gmail.com
Previous
Next Post »